Contact Us

| Phone Call

+605-281 2050

| WhatsApp

+6016-524 2819

| Email

ipneulic@ipneulic.com.my


I Pneulic Industries Supply Sdn Bhd
167, Hala Perusahaan Menglembu 13,
Kawasan Perindustrian Menglembu,
31450 Menglembu, Perak, Malaysia.
+605-2812050
+6016-5242819
+605-2820376

HDM VALVES, INTERMEDIATES ELEMENTS-- HDM VALVES

Previous 67 / 176 Next

HDM VALVES, INTERMEDIATES ELEMENTS-- HDM VALVES VALVE ISLANDS & FIELDBUS VALVES METAL WORK PNEUMATIC


HDM 6 Intermediate through
HDM 7 Intermediate blind
Flow-rate at 6 bar DP 1 bar (Nl/min) 00800
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Min temperature (°C) -10
Operating pressure (bar) Terminal 1-11= vacuum÷10 bar Terminal 1= 2÷7 bar
Protection degree IP65
Push-in fitting for pipe (Ø) 8

HDM elpn 5/2 bist. ø4 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 bist. ø4 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16 ( same as the max. no. of pilots )
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/2 single sol.ø4 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø4 - bist. man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø4 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø4 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 8 / 33
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/3 CC single sol.ø4 - single sol.man. Ctrl 24 VDC
HDM elpn 5/3 CC single sol.ø4 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

HDM elpn n°2 3/2 NCø4 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NCø4 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

HDM elpn n°2 3/2 NOø4 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NOø4 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

HDM elpn n°2 3/2 1 NO and 1 NCø4 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 1 NO and 1 NCø4 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 4
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC

HDM elpn 5/2 bist. ø6 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 bist. ø6 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/2 single sol.ø6 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø6 - bist. man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø6 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø6 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 8 / 33
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/3 CC single sol.ø6 - single sol.man. Ctrl 24 VDC
HDM elpn 5/3 CC single sol.ø6 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 300
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

HDM elpn n°2 3/2 NCø6 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NCø6 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

HDM elpn n°2 3/2 NOø6 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NOø6 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

HDM elpn n°2 3/2 1 NO and 1 NCø6 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 1 NO and 1 NCø6 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 6
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC

HDM elpn 5/2 bist. ø8 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 bist. ø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 650
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/2 single sol.ø8 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø8 - bist. man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø8 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 650
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 33
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/3 CC single sol.ø8 - single sol.man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 650
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

HDM elpn 5/3 CC single sol.ø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 300
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

HDM elpn n°2 3/2 NCø8 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NCø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 650
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

HDM elpn n°2 3/2 NOø8 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NOø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 650
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

HDM elpn n°2 3/2 1 NO and 1 NCø8 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 1 NO and 1 NCø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 650
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC

HDM elpn 5/2 bist. ø8 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 bist. ø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1000
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/2 single sol.ø8 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø8 - bist. man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø8 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1000
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 33
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/3 CC single sol.ø8 - single sol.man. Ctrl 24 VDC
HDM elpn 5/3 CC single sol.ø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

HDM elpn n°2 3/2 NCø8 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NCø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1000
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

HDM elpn n°2 3/2 NOø8 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NOø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1000
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

HDM elpn n°2 3/2 1 NO and 1 NCø8 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 1 NO and 1 NCø8 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1000
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC

HDM elpn 5/2 bist. ø10 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 bist. ø10 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/2 single sol.ø10 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø10 - bist. man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø10 - single sol.man. Ctrl 24 VDC
HDM elpn 5/2 single sol.ø10 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 33
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/2

HDM elpn 5/3 CC single sol.ø10 - single sol.man. Ctrl 24 VDC
HDM elpn 5/3 CC single sol.ø10 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 500
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 20 / 20
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 5/3

HDM elpn n°2 3/2 NCø10 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NCø10 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NC

HDM elpn n°2 3/2 NOø10 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 NOø10 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme n°2 3/2 NO

HDM elpn n°2 3/2 1 NO and 1 NCø10 - single sol.man. Ctrl 24 VDC
HDM elpn n°2 3/2 1 NO and 1 NCø10 - bist. man. Ctrl 24 VDC
Control PNP or NPN
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1200
Fluid Filtered air without lubrication; lubrication, if used, must be continuos
Insulation class F 155
Max temperature (°C) 60
Maximum number of pilots 16
Maximum number of valves 16
Min temperature (°C) -10
Pilot port (Pipe Ø) ø 4
Pliot pressure range 3÷7
Power 0.6 W
Protection degree IP 65 with common outlets
Push-in fitting for pipe (Ø) 8
TRA / TRR (ms) 8 / 45
Valve pressure range Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar
Voltage range in DC (VDC) 24 VDC ± 10%
Way scheme 3/2 NO + 3/2 NC
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version
Recent Updates
Subscribe Newsletter
1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start